TYPICAL LEVEL "A" FOUNDATION INSPECTION REPORT


File Number:Your special number.DOC




Inspection Address: 1000 Angel Street, Golden Gate City, Texas (Next to Heaven) Date: inspection date


TO:
Our Special Client
At You Address in
Your City, Texas (Next to Heaven)


SCOPE OF SERVICES:
This Report was prepared to Evaluate the condition of the Foundation at the above address, and make recommendations for remedial action if deemed necessary. This evaluation is based upon an interview with the occupant, owner and client, regarding a history of the property and performance of the structure. A request made to the client for any documents regarding the foundation, such as construction drawings, geotechnical reports, previous testing and inspection reports, and previous repair information. Information provided was reviewed. Visual observations were made during a physical walk-through. Observation of factors influencing the performance of the foundation were noted. The inspection included visual examination of the foundation and exterior finish, the external and internal fit of door and window frames, internal finish and such other factors which may effect the foundation as determined in the progress of the inspection. This is defined as a Level "A" inspection.

DISCUSSION:
This is to Certify that on the date above indicated, I personally inspected the building located at the referenced address and found the following:
1. The foundation is an integral reinforced concrete slab and grade-beam.
2. Observation of the interior and exterior indicate long-term deflection of the foundation having occurred.

RECOMMENDATIONS:
Stabilization and releveling of the perimeter grade-beam by means of underpinning piers is recommended.

Any open cracks in exterior brick should be cleaned before leveling. All exterior mortar shall be repaired with matching color mortar. Additional drainage should be provided, if shown on the attached drawing. If trees or other plants are shown "to be removed" this shall also be accomplished as part of the required work. All Piers shall be poured the same day their holes are drilled. This work should be accomplished by an experienced firm, in accordance with the attached Specifications. This report & specifications, are required to be on the job site during at all times the progress of work. The foreman or work supervisor shall be fluent in English and shall be on site during all inspections by the Engineer. This stabilization procedure should provide satisfactory service for the area stabilized, with proper maintenance.

QUALIFICATIONS:
Pilings of any kind are not acceptable. This includes steel, concrete and wood.
Both a 18" diameter and 12" diameter belled pier are specified. Either is acceptable.

LIMITATIONS:
This report is prepared from a visual inspection and applies only to the areas indicated to be stabilized and the remarks herein. Areas which are not shown to be stabilized may require stabilization in the future. It is not to be construed as any kind of guarantee or warrantee, as soils conditions and unforeseen conditions, such as plumbing leaks, changes in soil characteristics, improper maintenance, etc. may effect the structural behavior of any foundation.

CERTIFICATION OF WORK:
Certification of the work is required to close the city required permit. The Certifying Engineer may be required to inspect the pier installation as well as the completed work. The Contractor shall notify the Engineer prior to beginning any work on this project.

Sketch of structure

STABILIZATION & LEVELING OF FOUNDATIONS
USING 18" DIAMETER UNDERPINNING PIERS